Description
The Generac 7.5/6 KW PowerPact Air Cooled Standby Generator, Steel Enclosure, 8 Circuit LC is designed for reliable backup power, featuring rigorous testing for superior performance. Its True Power™ Electrical Technology ensures less than 5% Total Harmonic Distortion, providing utility-quality power suitable for sensitive electronics. The generator undergoes various evaluations, including NEMA MG1-22 and system torsional testing, and benefits from Generac’s extensive dealer network for comprehensive parts and service support. The PowerPact® model offers an affordable option for automatic backup power, and Generac’s transfer switches ensure long life and reliability with total system compatibility.
Includes:
- True Power™ Electrical Technology
- Digital LED controller
- Automatic transfer switch with built-in priority load center
- Rugged galvanneal steel rust resistant sound attenuated enclosure
- External main circuit breaker and control panel access
- UL 2200 listed
- Rated for winds up to 180 mph (289.7 km/h)
- Flexible fuel line connector
- Natural gas or LP gas operation
- 3 Year limited warranty
- Listed and labeled for installation as close as 18 in (457 mm) to a structure.*
*Must be located away from doors, windows, and fresh air intakes and in accordance with local codes.
Features and Benefits:
- Engine
- Generac (OHV) design: Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
- Cast iron cylinder walls: Rigid construction and added durability provide long engine life.
- Low oil pressure shutdown system: Shutdown protection prevents catastrophic engine damage due to low oil.
- High temperature shutdown: Prevents damage due to overheating.
- Generator
- Revolving field: Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
- Skewed stator: Produces a smooth output waveform for compatibility with electronic equipment.
- Displaced phase excitation: Maximizes motor starting capability.
- Automatic voltage regulation: Regulating output voltage to ±5% prevents damaging voltage spikes.
- UL 2200 listed: For your safety.
- Transfer Switch
- Fully automatic: Transfers vital electrical loads to the energized source of power.
- Remote mounting: Mounts near existing distribution panel for simple, low cost installation.
- Flush mountable: Can be installed between studs like a standard electrical panel.
- UL 1008 listed: For your safety.
- Digital Controls
- Multiple LED annunciation: Provides specific system information without having to open the generator enclosure.
- AUTO/OFF/MANUAL buttons: Select the operating mode.
- Utility voltage sensing: Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
- Utility interrupt delay: Prevents nuisance start-ups of the engine, setpoint approximately 5 seconds.
- Engine warm-up: Ensures engine is ready to assume the load, setpoint approximately 6 seconds.
- Engine cool-down: Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
- Cold Smart Start: If the ambient temperature is cold, allows the engine to warm up before load is applied.
- Seven day exerciser: Operates engine to prevent oil seal drying and damage between power outages.
- Smart battery charger: Maintains battery charge level to ensure starting.
- Main line circuit breaker: Protects generator from overload.
- Multiple protection features: Prevents additional damage from occurring within the generator if a fault condition arises.
- Unit
- UL weather protective enclosure: Sound attenuated enclosure ensures quiet operation and protection against mother nature. Three panels are removable for easy service and maintenance access.
- Enclosed critical grade muffler: Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
- Small, compact, attractive: Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.
- Installation System
- 14 in (35.6 cm) flexible fuel line connector: Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping.
Specifications:
- Generator
- Rated maximum continuous power capacity (LP): 7,500 Watts*
- Rated maximum continuous power capacity (NG): 6,000 Watts*
- Rated voltage: 240
- Rated maximum continuous load current – 240 volts (LP / NG): 31.25 / 25
- Main line circuit breaker: 35 amp
- Phase: 1
- Number of rotor poles: 2
- Rated AC frequency: 60Hz
- Power Factor: 1.0
- Battery requirement (not included): Group U1, 12 volts and 300 CCA minimum
- Unit weight (lb / kg): 280 / 127.3
- Dimensions (L x W x H) in / cm: 36 x 27 x 25 / 91.5 x 67.6 x 64.0
- Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load**: 69
- Engine
- Engine type: GENERAC OHV
- Number of cylinders: 1
- Displacement: 420 cc
- Cylinder block: Aluminum w/ cast iron sleeve
- Valve arrangement: Overhead valve
- Ignition system: Solid-state w/ magneto
- Governor system: Mechanical
- Starter: 12 VDC
- Oil capacity including filter: Approx. 1.2 qt/1.1 L
- Operating rpm: 3,600
- Fuel consumption:
- Natural Gas ft³/hr (m³/hr)
- 1/2 Load: 73 (2.07)
- Full Load: 117 (3.31)
- Liquid Propane ft3/hr (gal/hr) [L/hr]
- 1/2 Load: 31.6 (0.87) [3.29]
- Full Load: 51.6 (1.42) [5.37]
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges – 5–7 in water column (1.24–1.74 kPa) for NG, 10–12 in water column (2.49–2.99 kPa) for LP gas. For BTU content, multiply ft3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG).
- Controls
- LED indicators: Simple user interface for ease of operation.
- Mode buttons:
- AUTO: Automatic start on utility failure. 7 day exerciser.
- OFF: Stops unit. Power is removed. Control and charger still operate.
- MANUAL/TEST (start): Start with starter control, unit stays on. If utility fails, transfer to load takes place.
- Engine start sequence: Cyclic cranking: Engine cranks a maximum of five times at factory set intervals and durations.
- Engine warm-up: 6 sec (30 sec with Cold Smart Start)
- Engine cool-down: 1 min
- Starter lock-out: Starter cannot re-engage until five seconds after engine has stopped.
- 2.5 amp Smart Battery Charger: Standard
- Automatic voltage regulator: Standard
- Automatic low oil level shutdown: Standard
- Overspeed/Underspeed shutdown: Standard
- High temperature shutdown: Standard
- Overcrank protection: Standard
- Safety fused: Standard
- Wiring error detection: Standard
- Battery problem warning: Standard
- Charger problem warning: Standard
- RPM Sensor Loss shutdown: Standard
- Maintenance indicators (indicate break-in and regular maintenance is due): Standard
Rating definitions – Optional Standby: Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046, UL2200, and DIN6271).
* Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5% for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1% for each 10 °F (6 °C) above 60 °F (16 °C).
**Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.
Transfer Switch Features:
- Electrically operated, mechanically-held contacts for fast, positive connections.
- Rated for all classes of load, 100% equipment rated, both inductive and resistive.
- 2-pole, 240 VAC contactors.
- 60 millisecond transfer time.
- NEMA 1 (indoor rated) enclosure is standard.
- Multi listed for use with 1″ standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton, and Square D for the most flexible and cost effective install.
- Flush mountable.
Transfer Switch Specifications:
- No. of poles: 2
- Current rating (amps): 50
- Voltage: 120/240 1Ø
- Utility voltage monitor (fixed)*
- —Pick-up: 80%
- —Dropout: 65%
- Return to utility*: Approx. 15 sec
- Exerciser weekly for 12 minutes*: Standard
- ETL or UL Listed: Standard
- Total of pre-wired circuits
- No. 15 A 120 V: 8
- No. 20 A 120 V: 5
- No. 20 A 240 V: 1
- No. 30 A 240 V: –
- No. 40 A 240 V: 1
- No. 50 A 240 V: –
- Tandem breaker capability: 8 spaces
- Circuit breaker protected
- Available RMS symmetrical fault current @ 240 V 10,000
- Weight (lb / kg): 20 / 9.1
- Installation whips included: No
*Function of controller